Skip navigation links

When performing a static calibration of the Vector system the system will return a code that indicates either the successfully completion of the calibration (0) or a value that is communicating one or more error conditions.

The code that is returned is the sum of the different conditions.

For example if a code of 514 is received then that this is the sum of code 2 and 512.

Right Left Meaning
0 0 Success
2 512 Calibration timeout – the calibration didn’t complete, because it kept on restarting due to noise
4 1024 Pedaling detected – the user started pedaling while the system was trying to calibrate
16 4096 Pedal to Pedal transmit timeout – the right side was not able to get the calibration message out within the required timeframe
32 8192 Pedal to Pedal receive timeout – the right side did not receive a response from the left side within the required timeframe

These codes can occur simultaneously so they are all added together to provide a resultant code.